Skip to main content

Analog In

These commands are available three ways — in the FREE-WILi GUI app, in a serial terminal, and on the device itself. See Connecting it to a computer for how to reach them.

Stream Analog In

Streams analog input values to the host at the given rate.

How to use it — press s. At the prompt, enter: Sample Time in milliseconds.

What you enterstream_rate_ms.

Read TLA2024

Reads the latest TLA2024 voltages for all 4 channels.

How to use it — press r.

Config TLA2024 Channel

Configures a TLA2024 channel: mux 0-7 = A0-A1,A0-A3,A1-A3,A2-A3,A0-GND,A1-GND,A2-GND,A3-GND; range 0-5 = 6.144V,4.096V,2.048V,1.024V,0.512V,0.256V.

How to use it — press c. At the prompt, enter: channel (0-3), mux (0-7), range (0-5).

What you enterchannel, mux, range.

TLA2024 Data Rate

Sets the TLA2024 data rate: 0-6 = 128,250,490,920,1600,2400,3300 SPS.

How to use it — press f. At the prompt, enter: data rate (0-6).

What you enterrate.

Stream TLA2024

Streams TLA2024 voltages to the host at the given rate (0 stops).

How to use it — press t. At the prompt, enter: Sample Time in milliseconds.

What you enterstream_rate_ms.

See also: Analog IO panel — the on-screen panel for this.